10 AWG industriell skjermet TC-ER brettkabel PVC Nylon PVC 600V

10 AWG industriell skjermet TC-ER brettkabel PVC Nylon PVC 600V
Details:
·PVC overall jakke
·Fullglødet bart kobber klasse B
· Polyvinylklorid (PVC) dekket
·Filler (etter behov)
· Spenning: 600V
· Temperatur: Vurdert til 90 grader vått eller tørt
·Størrelsesområde: Tilgjengelig i 18 til 10 AWG
·Standard:UL83/UL1277
·Tilgjengelig i 2 til 37 ledere
·Farge:I henhold til ICEA S-58-679 Metode 1, Tabell E-2; ekstra fargekodingsalternativer tilgjengelig
Send Inquiry
Download
Beskrivelse
Tekniske parametere
Sertifisering

600V control cable for factory automation

PRODUKT REAL SHOT

 

VNTC tray cable for PLC wiring
600V control cable for channel
TC-ER control cable for direct burial

THHN PVC tray cable for trough

10 AWG skjermet PVC Nylon PVC 600V Industriell TC-ER brettkabel for underjordisk
Dette10 AWG industriell skjermet TC-ER-brettkabeler høy-ytelseTHHN PVC-brettkabel for underjordisk, sertifisert holdbarTC-ER-kontrollkabel for utendørs, og spesielt konstruert somTC-ER-kontrollkabel for støttet av messenger-ledning. Konstruert med trippel-lags PVC/Nylon/PVC THHN-isolasjon, mylarfolie i full aluminium og UV/fuktbestandig sort PVC-kappe, håndterer den underjordisk nedgraving, frilagt utendørs brettruting og messenger-trådantenneinstallasjon i våt/tørr industriell kraftkontrollkretser med NEC-klassifisert UL.90.
PRODUKTSPESIFIKASJONER

 

600V control cable for outdoor

Produktbeskrivelse

 

PVC/Nylon/PVC (THHN/THWN-2), 600V Control, Type TC-ER og Direct Burial Cables består av fullstendig utglødd bare kobber klasse B ledere, dekket med olje- og gassbestandig polyvinylklorid (PVC) og klar nylonisolasjon, uskjermet eller skjermet og svart PVC. Disse kablene brukes i industrielle kraft- eller stasjonskontrollkretser.

Søknader

 
  • I ledninger, kanaler, fri luft, løpebaner og direkte nedgraving inkluderer primærinstallasjoner kabelbakker og utendørsplasseringer

  • På våte eller tørre steder

  • Godkjent for klasse I, Div. 2 industrifarlige steder i henhold til NEC

  • Tillatt for Exposed Run (ER) brukt i samsvar med NEC for 3 eller flere ledere; to ledere uten jordledning er kun type TC

Funksjoner

 
  • Vurdert til 90 grader vått eller tørt
  • Ripcord (etter behov)
  • Utmerket motstand mot sollys
  • Oppfyller kaldbøytest ved -25 grader
SPESIFIKASJONER

Konduktørtall

Tilgjengelig i 2 til 37 ledere

Dirigent

Fullglødet bart kobber klasse B

Målestørrelser

Tilgjengelig i 18 til 10 AWG

Isolasjon

Polyvinylklorid (PVC) dekket
• 14 AWG og større er type THHN/THWN-2
Fargekoding I henhold til ICEA S-58-679 Metode 1, Tabell E-2; ekstra fargekodingsalternativer tilgjengelig
Fyllstoffer Ikke-hygroskopiske fyllstoffer, etter behov for å oppnå et sirkulært tverrsnitt
Skjold (valgfritt) Samlet aluminiumspolyester (mylar) folie i kontakt med 20 AWG trådet fortinnet kobberavløpstråd
Jakke Polyvinylklorid (PVC)

Jakkemerking

Lederstørrelser 18 AWG – 16 AWG: 00000 FT GREATER WIRE CABLE XXAWG XX/C PVC/NYLON PVC JKT (eller OS) 600V 90C VÅT ELLER TØRR TYPE TC (eller -ER) (UL) SUN RES DIR CH200 BUR 1 MMDDYYYYLederstørrelser 14 AWG – 10 AWG: 00000 FT STØRRE WIRE KABEL XXAWG XX/C THHN/THWN-2 PVC JKT (eller OS) 600V 90C VÅT ELLER TØRR TYPE TC (eller BURNER) FT4/IEEE1202 MADE IN KINA MMDDYYYY

Emballasje

Ikke-returbare tresneller i en rekke lengder og dimensjoner

Ytelsesoverholdelse

ASTM B8, ASTM B33

UL 83

UL 1277

UL 1685 (flammeeksponeringstest)

ANSI/NEMA WC 70/ICEA S-95-658

ANSI/NEMA WC 57/ICEA S-73-532

NEC

Andre samsvar

EPA 40 CFR, del 261

OSHA

RoHS-kompatibel/RoHS 2-kompatibel

REACH-kompatibel

Uskjermet

Konduktørtall Lederstørrelse AWG Isolasjonstykkelse
i (mm)
Jakke tykkelse
i (mm)
Ca. Total diameter
i (mm)
Ca. Nettovekt
lbs/kft (kg/km)

2

18 0.020(0.51) 0.045(1.14) 0.28(7.1) 40(56)
3 18 0.020(0.51) 0.045(1.14) 0.29(7.5 50 (69)
4 18 0.020(0.51) 0.045(1.14) 0.32(8.0) 60(84)
5 18 0.020(0.51) 0.045(1.14) 0.34(8.7) 70(99)
7 18 0.020(0.51) 0.045(1.14) 0.37(9.4) 85(126)
9 18 0.020(0.51) 0.045(1.14) 0.43(10.9) 110(158)
12 18 0.020(0.51) 0.045(1.14) 0.47(12.0) 135(199)
19 18 0.020(0.51) 0.045(1.14) 0.55(14.0) 205(298)
25 18 0.020(0.51) 0.060(1.52) 0.67(17.1) 280(414)
37 18 0.020(0.51) 0.060(1.52) 0.76(19.4) 390(573)
2 16 0.020(0.51) 0.045(1.14) 0.30(7.7) 50 (69)
3 16 0.020(0.51) 0.045(1.14) 0.32(8.1) 60(88)
4 16 0.020(0.51) 0.045(1.14) 0.35(8.8) 75(109)
5 16 0.020(0.51) 0.045(1.14) 0.37(9.5) 90 (130)
7 16 0.020(0.51) 0.045(1.14) 0.40(10.3) 115(168)
9 16 0.020(0.51) 0.045(1.14) 0.47(12.0) 145(211)
12 16 0.020(0.51) 0.045(1.14) 0.52(13.3) 185(269)
16 16 0.020(0.51) 0.060(1.52) 0.61(15.6) 255(378)
19 16 0.020(0.51) 0.060(1.52) 0.64(16.4) 295(435)
25 16 0.020(0.51) 0.060(1.52) 0.75(18.9) 380(560)
30 16 0.020(0.51) 0.060(1.52) 0.79(20.0) 440(653)
37 16 0.020(0.51) 0.060(1.52) 0.85(21.5) 530(784)
2 14 0.020(0.51) 0.045(1.14) 0.33(8.4) 60(88)
3 14 0.020(0.51) 0.045(1.14) 0.35(8.8) 80(115)
4 14 0.020(0.51) 0.045(1.14) 0.38(9.6) 100(143)
5 14 0.020(0.51) 0.045(1.14) 0.41(10.4) 120(172)
7 14 0.020(0.51) 0.045(1.14) 0.45(11.3) 155(226)
9 14 0.020(0.51) 0.045(1.14) 0.52(13.2) 195(285)
12 14 0.020(0.51) 0.060(1.52) 0.61(15.5) 265(393)
19 14 0.020(0.51) 0.060(1.52) 0.71(18.1) 400(591)
25 14 0.020(0.51) 0.060(1.52) 0.83(21.0)   515(763)
30 14 0.020(0.51) 0.060(1.52) 0.87(22.2)    605(895)
37 14 0.020(0.51) 0.080(2.03) 0.98(25.0) 765(1,138)
2 12 0.020(0.51) 0.045(1.14) 0.37(9.3) 80(117)
3 12 0.020(0.51) 0.045(1.14) 0.39(9.8) 110(157)
4 12 0.020(0.51) 0.045(1.14) 0.42(10.7) 135(198)
5 12 0.020(0.51) 0.045(1.14) 0.46(11.7) 165(240)
7 12 0.020(0.51) 0.045(1.14) 0.50(12.7) 215(318)
9 12 0.020(0.51) 0.060(1.52) 0.62(15.7) 290(431)
12 12 0.020(0.51) 0.060(1.52) 0.69(17.4) 375(553)
19 12 0.020(0.51) 0.060(1.52) 0.80(20.3) 565(840)
25 12 0.020(0.51) 0.080(2.03) 0.98(24.8) 775(1,147)
30 12 0.020(0.51) 0.080(2.03) 1.03(26.2) 905(1,344)
37 12 0.020(0.51) 0.080(2.03) 1.11(28.2) 1,090(1,622)
2 10 0.025(0.64) 0.025(0.64) 0.43(11.0) 115(169)
3 10 0.025(0.64) 0.025(0.64) 0.46(11.7) 160(231)
4 10 0.025(0.64) 0.025(0.64) 0.50(12.8) 200(295)
5 10 0.025(0.64) 0.025(0.64) 0.58(14.8) 260(385)
7 10 0.025(0.64) 0.025(0.64) 0.63(16.1) 345(511)
9 10 0.025(0.64) 0.025(0.64) 0.74(18.9) 435(647)
12 10 0.025(0.64) 0.025(0.64) 0.83(21.0) 565(836)

 

Samlet skjermet

Antall par Lederstørrelse AWG Isolasjonstykkelse
i (mm)
Jakke tykkelse
i (mm)
Ca. Total diameter
i (mm)
Ca. Nettovekt
lbs/kft (kg/km)

2

18 0.020(0.51) 0.045(1.14) 0.28(7.2) 45(62)
3 18 0.020(0.51) 0.045(1.14) 0.30(7.5) 55(76)
4 18 0.020(0.51) 0.045(1.14) 0.32(8.1) 65(91)
5 18 0.020(0.51) 0.045(1.14) 0.34(8.8) 75(106)
7 18 0.020(0.51) 0.045(1.14) 0.37(9.4) 90(133)
9 18 0.020(0.51) 0.045(1.14) 0.43(10.9) 115(165)
12 18 0.020(0.51) 0.045(1.14) 0.48(12.1) 140(207)
19 18 0.020(0.51) 0.045(1.14) 0.56(14.1) 210(306) 
25 18 0.020(0.51) 0.060(1.52) 0.68(17.2) 285(423)
37 18 0.020(0.51) 0.060(1.52) 0.77(19.5) 395(583)
2 16 0.020(0.51) 0.045(1.14) 0.31(7.8) 55 (76)
3 16 0.020(0.51) 0.045(1.14) 0.32(8.2) 65(95)
4 16 0.020(0.51) 0.045(1.14) 0.35(8.9) 80(116)
5 16 0.020(0.51) 0.045(1.14) 0.38(9.6) 95(137)
7 16 0.020(0.51) 0.045(1.14) 0.41(10.4) 120(175)
9 16 0.020(0.51) 0.045(1.14) 0.47(12.1) 150(219)
12 16 0.020(0.51) 0.045(1.14) 0.53(13.4) 190(277)
16 16 0.020(0.51) 0.060(1.52) 0.62(15.7) 265(387)
19 16 0.020(0.51) 0.060(1.52) 0.65(16.4) 300(444)
25 16 0.020(0.51) 0.060(1.52) 0.75(19.0) 385(569)
30 16 0.020(0.51) 0.060(1.52) 0.79(20.1) 450(663)
37 16 0.020(0.51) 0.060(1.52) 0.85(21.6) 535(794)
2 14 0.020(0.51) 0.045(1.14) 0.33(8.4) 65(94)
3 14 0.020(0.51) 0.045(1.14) 0.35(8.9) 65(95)
4 14 0.020(0.51) 0.045(1.14) 0.38(9.6) 85(121)
5 14 0.020(0.51) 0.045(1.14) 0.41(10.4) 105(150)
7 14 0.020(0.51) 0.045(1.14) 0.44(11.3) 125(179)
9 14 0.020(0.51) 0.045(1.14) 0.52(13.2) 160(232)
12 14 0.020(0.51) 0.060(1.52) 0.61(15.4) 200(292)
19 14 0.020(0.51) 0.060(1.52) 0.71(18.0) 270(400)
25 14 0.020(0.51) 0.060(1.52) 0.82(20.9) 405(597)
30 14 0.020(0.51) 0.060(1.52) 0.87(22.0) 520(770)
37 14 0.020(0.51) 0.080(2.03) 0.98(24.8) 610(1,144)
2 12 0.020(0.51) 0.045(1.14) 0.37(9.3) 85(124)
3 12 0.020(0.51) 0.045(1.14) 0.39(9.8) 110(163)
4 12 0.020(0.51) 0.045(1.14) 0.42(10.7) 140(205)
5 12 0.020(0.51) 0.045(1.14) 0.46(11.6) 170(246)
7 12 0.020(0.51) 0.045(1.14) 0.50(12.6) 220(325)
9 12 0.020(0.51) 0.060(1.52) 0.62(15.6) 295(438)
12 12 0.020(0.51) 0.060(1.52) 0.68(17.3) 380(560)
19 12 0.020(0.51) 0.060(1.52) 0.80(20.2) 570(846)
25 12 0.020(0.51) 0.080(2.03) 0.97(24.6) 775(1,153)
30 12 0.020(0.51) 0.080(2.03) 1.02(26.0) 910(1,350)
37 12 0.020(0.51) 0.080(2.03) 1.10(28.0) 1,095(1,627)
2 12 0.020(0.51) 0.045(1.14) 0.43(11.0) 120(176)
3 10 0.025(0.64) 0.045(1.14) 0.46(11.7) 160(238)
4 10 0.025(0.64) 0.045(1.14) 0.50(12.8) 205(302)
5 10 0.025(0.64) 0.060(1.52) 0.58(14.7) 265(392)
7 10 0.025(0.64) 0.060(1.52) 0.63(16.0) 350(517)
9 10 0.025(0.64) 0.060(1.52) 0.74(18.8) 440(654)
12 10 0.025(0.64) 0.060(1.52) 0.82(20.9) 570(843)
 
SERTIFISERINGER

 

TC-ER control cable for indoor

EMBALLASJE

 

600V control cable for conduit

Rulle

TC-ER control cable for duct

Spole av plast

THHN PVC tray cable for ventilated tray

Liten tresnelle

SØKNAD

 

TC-ER control cable for ladder tray
Fabrikkautomatisering
600V Type TC cable UL listed
Prosessinstrumentering
90C dry 75C wet TC-ER cable
Kontrollsystemer for vannbehandling
SAK

 

UL Type TC-ER-JP cable

BASF Ludwigshafen Verbund Site

TC-ER-JP tray cable

MWRA Deer Island avløpsrenseanlegg

UL listed direct burial tray cable

Siemens Electronic Works Amberg Factory

HVORFOR VELGE OSS

 

30År med erfaring
i én{0}}tjeneste

Dongguan Greater Wire & Cable Co., Ltd. er en profesjonell kabelprodusent av-kvalitet i Kina, som leverer sertifiserte elektriske kabelløsninger for bygge-, industri-, gruve-, energi- og infrastrukturprosjekter over hele verden.

Med en 30 000 m² fabrikk, 30 produksjonslinjer, erfarne ingeniører og et strengt kvalitetskontrollteam, tilbyr vi pålitelige, sporbare og kompatible kabelprodukter for internasjonale ingeniørapplikasjoner. Produktene våre støttes av sertifiseringer inkludert SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS og ISO.

Vi er forpliktet til sikkerhet, kvalitet, åpenhet og langsiktig-partnerskap. Fra råvareinspeksjon til ferdig produkttesting, er hver batch nøye kontrollert for å sikre stabil ytelse og pålitelig prosjektbruk.

Større kabel --sertifisert kvalitet. Pålitelig forsyning. Engineering verdi.

NEC Article 725 Class 1 control cable
 
15K
Ferdige prosjekter
150+
profesjonelle ansatte
15K
fornøyde kunder
92+
priser og sertifikater
ANLEGGSUTSTYR

 

NEMA WC70 tray cable
 
CSA FT4 tray cable
 
NEC 336.10 exposed run cable
 
UL Type TC cable 600V
 
ICEA S-58-679 color code control cable
 
FT4 flame rated TC-ER cable
 
GLOBALE SERTIFISERINGER

 

UL 83 THHN control cable

KUNDEBILDER
 

Class 1 Div 2 TC-ER tray cable

INTERNASJONAL TRANSPORT

 

01

Sjøfrakt

Vi tilbyr pålitelige sjøfraktløsninger for store-volumsbestillinger. Varene dine er sikkert pakket og sendt i containere, noe som sikrer kostnadseffektiv-levering til havner over hele verden.

02

Luftfrakt

For raskere levering sikrer vår luftfrakttjeneste at produktene dine når internasjonale destinasjoner raskt, med forsiktig håndtering og full sporing underveis.

03

International Express

Trenger du hasteforsendelser? Vår internasjonale ekspresstjeneste leverer små til mellomstore bestillinger effektivt, og gir dør-til-dør-tjeneste med sann-sporing for trygghet.

commercial PVC/Nylon/PVC control cable
SAMARBEIDSPARTNER

 

Vi ser etter en samarbeidspartner for å utvide virksomheten vår.

industrial 600V tray cable
industrial PVC/Nylon/PVC control cable
industrial Type TC-ER control cable
industrial TC-ER control cable
industrial TC-ER tray cable
commercial Type TC-ER control cable
Class 1 Div 2 PVC/Nylon/PVC control cable
UL 83 THHN/THWN-2 tray cable
IEEE 1202 FT4 tray cable
NEC Article 501 Class 1 Div 2 cable
Hvordan samarbeide med oss?

Bare del kravene dine, motta vår profesjonelle løsning, bekreft prøver og nyt rask, pålitelig produksjon og verdensomspennende levering - å jobbe med oss ​​er så enkelt.

Adressen vår

Bygning 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong-provinsen, Kina

Telefonnummer

+86 136 6257 9592

+86 135 1078 4550

E-post

manager01@greaterwire.com

ASTM B3 copper control cable
FAQ

 

Hvilke fordeler gir dette somTHHN PVC-brettkabel for underjordisk?
Dens vann-, jord- og korrosjonsbestandige PVC-ytre jakke sammen med olje-bestandig THHN-nylonisolasjon gir lang levetid for direkte underjordisk nedgraving uten ekstra beskyttelse mot rør.
Hvorfor velge denne som pålitelig TC-ER-kontrollkabel for utendørs bruk?
Kabelen har utmerket sollysmotstand og bredt -25 grader til 90 graders driftstemperaturområde, fullt kvalifisert for alle utsatte utendørs industrielle kablingsscenarier i henhold til NEC TC-ER-standarder.
Kan denne brukes som TC-ER-kontrollkabel for støtte for antenneledninger med messenger?
Ja, dens robuste runde kabelstruktur og strekkbalanserte design støtter installasjon opphengt av messenger-wire for overhead utendørs industrielle kontrollkablingsprosjekter.
Hvilke standard installasjonsmetoder støtter denne skjermede TC-ER-kabelen?
Den passer til kabelbakker, rør, underjordisk direkte nedgraving, synlige utendørs løp og messenger wire-støttet luftledning for industrielle strøm- og kontrollkretser.

 

Hot Tags: 10 awg industriell skjermet tc-er skuffkabel pvc nylon pvc 600v, Kina 10 awg industriell skjermet tc-er tray kabel pvc nylon pvc 600v produsenter, leverandører, fabrikk

Send Inquiry